| Part name | material |
| valve body | |
| Valve plate | 310S/2520 alloy steel/CF8 |
| valve seat | 10S/2520 alloy steel/CF8 |
| valve stem | Alloy steel (hard chrome plating treatment) |
| filler | Enhanced graphite/carbon fiber |
| Standard configuration includes quick release valve, magnetic induction limit or mechanical limit |
| Fault phenomenon | Cause diagnosis | Troubleshooting methods |
| Flange connection is not sealed (leakage) | Is the working surface of the valve intact | Repair flange working surface/replace flange |
| Is the valve deformed | Replace and add flange gasket | |
| Is the bolt tight and even | Evenly adjust bolts to loosen | |
| The valve is not sealed (internal leakage) | Is the valve in place | Remove stuck foreign matter |
| Is the valve seal intact | Clean and replace seal pair | |
| The valve does not open or close smoothly | Is the cylinder bumped | Replace cylinder |
| Is the air pressure insufficient or full | Inspect air supply pipeline | |
| Is the valve body transmission component abnormal | Adjust and replace parts |